Keep an eye on vibrations during machine start-up.

In the case of Machinery start-up can be undesirable Vibrations occur. Wireless vibration sensors detect vibrations in a time-synchronous manner. Tracking She live as herself Vibrations develop on different machine components as a function of the cycle time.

Machine part with blue multi-sensor node

The machine reaches its target cycle time.

Now vibrations occur.

Your task

The machine runs for the customer for the first time with the required cycle time. Now you need to check if the movements go as planned.

Your problem

At higher speed, new vibrations arise. They feel these on the gripper or rack – but do not yet know where they arise.

Keep an eye on vibrations better

Measure simultaneously on the drive, on the machine frame and on the affected process and recognize differences between the measuring points and cycle times of the machine. So you can continue your troubleshooting more targeted.

Install sensors

Attach wireless vibration sensors to the drive, rack and affected machine station.

Raising the machine

Drive the machine until the target cycle time. The sensors detect the vibrations at the measuring points.

Compare data

Take a look at the measurement curves together and limit conspicuous vibration sources.

Why it works – two reasons

Compare measuring points directly – through a common time base
The sensors detect vibrations in a time-synchronous manner. As a result, temporal relationships between the measurement points can be examined instead of only considering individual measurement curves that are separate from one another.

Measure faster – with wireless sensors
They bring The sensors at the relevant points without having to lay measuring cables through the machine. In this way, measurement points can be quickly supplemented or displaced if necessary.

FAQ - Frequent General Questions

How quickly do I get the first usable results after installation?

The First data Usually run after ca. 10 minutes one. With simple evaluation techniques (trends, basic checks) can be started immediately after installation. For robust predictive models, additional history is required depending on the target.

As a sensor node, we call our Multi-sensor. Each multi-sensor consists of a printed circuit board with 10 individual sensors: vibration/vibration (acceleration), gyro, magnetic field, temperature, humidity, air pressure, VOC/BVOC, eCO2, IAQ index and light. In addition, further external sensor parameters can be connected (depending on the setup).

As standard, a system with 5 sensor nodes is supplied. For a press motor, many customers start with 1–2 sensor nodes, to collect vibration data on the motor/bearing (plus optional temperature). For the whole press system often come Multiple points at bearing points/gearboxes/drives thereto. (This depends heavily on mechanics, accessibility and the expected error pattern.)

There are several mounting options – depending on how "fast" or "industrialized" it should be:

  • Very simple and flexible: double-sided adhesive tape or Cable tie
  • robust/individual: screw-on mounting plates or customer-specific holder/housing
  • depending on the measurement point also possible: Magnetic assembly
    Important is always an Fixed, vibrational fidelity Attachment to the desired measuring point.

This depends heavily on the use case – especially on the Sample rate:

  • at High frequency vibration (maximum load) the running time is typically at 3–4 days
  • at few measurements (e.g. every 15 minutes for 2 minutes) a sensor node can several months running.

 

If a permanently high measuring load is required, the energy supply can also be ensured via the power grid by wiring.

In principle, yes. By default, we work with our sensor node ecosystem, but existing sensor technology can be integrated depending on the signal/interface – typically via MQTT or REST, or via the gateway with Bluetooth. If there is no direct standard connection, it is an integration project.

FAQ - Frequent technical questions

Which radio/cable standards do sensor and gateway talk about with which range?

sensor node to gateway runs over Bluetooth Low Energy (BLE). Gateway to cloud typically runs over LTE or WLAN. The range depends on the environmental conditions; In practice, depending on the bandwidth/data load, we typically up to about 10 meters around the gateway.

This depends heavily on the use case or on the data rate:

  • at High frequency vibration/oscillation data are typically 2–3 sensor nodes per gateway realistic
  • A system is usually from 5 sensor nodes Delivered
  • at Environmental data (e.g. temperature/moisture) are also up to about 10 sensor nodes Possible

Standard is the connection by LTE/WLAN into the cloud. If data is to remain local, the gateway can also transfer data to a Customer-side MQTT brokers or in one of the Customer-side database transferred. Typical integrations are MQTT and REST.

Typical: Mount sensor nodes → Name measurement points in the dashboard → Check data. For pure monitoring, this can be done within A few minutes. Standard data evaluation included. When a complex AI use case is implemented, data/target definition and acceptance are added.

Updates are usually carried out via Remote mechanisms (Gateway/Backend) so that the systems remain up to date.

FAQ - Frequent questions about the data

What sampling rates are possible?

For vibration are up to 800 Hz possible (in short also up to 12kHz). Other environmental sensors typically run slower.

In principle, they shall: Raw data. During processing (e.g. by AI), it can be decided whether Raw data stored or if only Aggregated/processed values (features/results) to the database and displayed in the dashboard.

By default, these data are Cloud on German, GDPR-compliant servers stored. Alternatively, the gateway data can also be Customer-side MQTT or one of Customer-side database supply.

If raw data is written to our internal database, the Memory duration configured will become. Typical guidelines are – depending on the amount of data and customer requirements – with ca. 1 to 12 months.

This can run on two tracks: you get Automatic evaluations (dashboards/alarms/models), and We support during setup and interpretation – depending on whether you prefer self-service or support in the project.

Typical: Define goal → collect data → test features/models → validate → put into operation. The duration of A few weeks (Anomaly/Trend) to several months (Regression/RUL), depending on how many relevant events/pauses exist as a learning base.

We offer a Update service (various terms possible, at least 2 years included), with which the system Remote update is kept up-to-date. Also included Fault analysis in many cases run very well remotely: For each system component, a Remote service order are requested to examine causes and to derive measures.

Why vibrations can occur during machine start-up

When an industrial machine is put into operation, the movement speed is often increased stepwise. The machine should finally reach the agreed target cycle time and work precisely, calmly and reliably.

With increasing speed, the dynamic loads change. Drives accelerate faster, moving components are loaded more and braking or positioning processes can stimulate new vibrations.

It can happen that a machine works inconspicuously during slow movements, but vibrates clearly at higher speed.

These vibrations can have various causes. For example, a drive, an unfavorable mechanical Coupling or resonance in the machine frame.

For the machine manufacturer, this creates a concrete task: He must determine where the conspicuous vibrations arise and via which components they propagate.

Why the location of the strongest vibration is not necessarily the cause

An oscillation can occur at one point of the machine and propagate via mechanically coupled components.

One example is a drive which introduces vibrations into the machine frame. They finally reach a positioning station via the construction. There, they may interfere with the quiet setting down or picking up of a workpiece.

The machine manufacturer first notices the problem at the positioning station, although the actual excitation originates from another unit.

The measuring point with the highest oscillation amplitude is not necessarily the place of origin. Resonances, damping and the design of the machine affect how much vibration occurs at a particular location.

Therefore, it can be helpful to measure several points at the same time.

Why individual measurement points can make troubleshooting more difficult

Anyone who measures vibrations sequentially at different points of a machine may compare different operating states.

Even small changes in the movement sequence, in the machine load or in the cycle can influence the measured values.

Signals detected at the same time have a decisive advantage: they describe the behavior of the individual measuring points during the same machine process.

In this way, recurring movements can be examined and conspicuous events can be compared at several points.

This does not replace technical interpretation, but creates a better basis for the search for possible causes.

How orbit measures vibrations in multiple locations simultaneously

The orbit measuring system uses wireless sensor nodes that detect vibrations at selected points of a machine.

Depending on the measurement task, the sensors can be mounted, for example, on drives, bearing regions, load-bearing machine parts or on a sensitive positioning unit.

For a first measurement setup, the points between which a mechanical relationship is assumed are selected. A typical design can comprise, for example, a sensor on the drive, a sensor on the machine frame and a sensor on the relevant positioning station.

While the machine is working, the sensors detect their vibration signals. The gateway collects the data and makes it available for joint evaluation.

The importance of time synchronization

In order for the oscillations of different measuring points to be examined together in a meaningful manner, the detected measured values must match one another in time.

Time synchronization establishes a common time reference.

As a result, the machine manufacturer can examine, for example, whether conspicuous vibration events occur at several measuring points during the same machine cycle.

Time shifts between the signals can also be analyzed, provided that sampling rate, synchronization accuracy and signal quality are sufficient for this.

However, the common time base alone does not automatically determine from which direction an oscillation propagates. For this purpose, the mechanics, the signal shapes and the measurement conditions must be taken into account.

How to keep an eye on vibrations with the orbit system

By looking at this information together, possible causes can be narrowed down.

For example, a conspicuous frequency can occur simultaneously at the drive and at the frame. This relationship can be an indication that both are mechanically coupled or are influenced by the same excitation.

Additional measurement points, targeted changes in the operating state or further analyses may be necessary for a clear determination of the cause.

Why wireless sensors are helpful in commissioning

During commissioning, the measuring tasks change frequently.

First, maybe the drive is being studied. Subsequently, it is to be checked how strongly the vibration has an effect on the frame or on a sensitive positioning station.

Wireless sensors make it possible to reposition measuring points without additional signal lines. This eliminates some of the expense for cable laying.

This can facilitate the construction in particular at machine regions which are difficult to access or at changing measuring points.

What the mechanical engineer can do with the results

At the end of a measurement, there is not automatically a finished error diagnosis.

Rather, the measurement data helps to answer specific technical questions: In which operating state does the abnormality occur? Which measurement points show similar vibration components? Which parts of the machine should be examined next?

With this information, the machine manufacturer can decide more specifically where to carry out further measurements or which mechanical components to check.

After a design change, the same measuring setup can be used again. This makes it possible to compare whether and how the vibrations have changed.

Where the limits of the measurement procedure are

Not every cause of vibration can be unambiguously determined by a comparison of acceleration signals alone.

The significance depends, among other things, on the measuring positions, the sensor fastening, the investigated frequencies and the operating conditions.

Very short or high-frequency oscillation events also require a sufficiently high sampling rate.

The suitable sensor arrangement and evaluation should therefore be adapted to the specific machine and the question to be examined.

EnglishenEnglishEnglish

Download data sheet

Find causes of vibrations faster.